Abstract

To estimate the diagnostic accuracy of sentinel node biopsy (SNB) combined with preoperative (18) F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) for inguinal lymph node (LN) evaluation in patients with invasive penile squamous cell carcinoma (PSCC) with no clinical evidence of inguinal metastases (cN0) at two tertiary centres with complete clinical follow-up. From April 2010 in Centre one and from January 2013 in Centre two, we prospectively enrolled patients diagnosed with invasive PSCC and scheduled for SNB at the only two university centres treating penile cancer in Denmark. All patients had FDG PET/CT before SNB. The sentinel LNs were preoperatively located by planar lymphoscintigraphy in 134 groins (68 patients) and by single-photon emission CT/CT in 120 groins (61 patients). The primary endpoints were the sensitivity, specificity, and false-negative rate of SNB combined with FDG PET/CT. The secondary endpoint was SNB-related morbidity. We examined 254 groins in 129 patients by SNB combined with FDG PET/CT. The median (interquartile range, IQR) follow-up of survivors was 23 (14-35)months. Of 201 LN-negative groins, two were false negatives, and despite radio-chemotherapy treatment, both patients died from penile cancer. Four of 23 radiotracer-silent groins, had a FDG PET/CT-positive LNs and were surgically explored. In one of four of the explored groins, a positive LN was found. Combined FDG PET/CT-SNB sensitivity was 94.4% (95% confidence interval [CI] 81-99%) per groin. The false-negative rate was 5.6% (95% CI 1-19%) per groin. In 15 patients (11.6%) there were 25 SNB-related complications of Clavien-Dindo grades I-IIIa. The only Clavien-Dindo IIIa complication was an inguinal lymphocele treated by aspiration. In this study, we present a favourable SNB false-negative rate of 5.6% in a national cohort of clinically LN-negative patients with invasive PSCC with a pre-SNB FDG PET/CT scan. The combination of FDG PET/CT and SNB seems to be a promising diagnostic approach. Even so, a false-negative SNB was fatal in two of two cases and we are determined to continue the development of our SNB technique. The SNB-related morbidity was limited.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.