Abstract

In orthopedic surgery and particularly in total hip arthroplasty, fixation of femoral implant is generally made by the surgical cement. Bone–cement interface has long been implicated in failure of cemented total hip replacement (THA), it is actually a critical site that affect the long-term stability and survival of prosthetic implants after implantation. The main purpose of this study is to investigate the effect of cement penetration into the bone on damage scenario at the interface. Previously most researchers have been performed to study damage accumulation in the cement mantle for different amount of cement penetration. In this work, bone–cement interface integrity has been studied for different mechanical properties. Cohesive traction separation law is used to detect contact damage between cement and bone. Results showed that a larger debonded area was predicted proximally and distally. Adhesion between bone and cement is affected mainly by cement penetration into the bone. Higher cement penetration into the bone leads to a good load transfer. A lower strength of the bone–cement interface due to a lower mechanical property results in faster interface damage. So we advise surgeons to well perpetrate the bone for long-term durability of cemented THA.

Highlights

  • The use of total hip replacement (THR) prosthesis has become the second most performed surgical procedure every year, it aims to replace the defective natural articulation [1]

  • We have shown the effect of different amounts of interdigitated bone within the cement on damage and stress distribution

  • The effect of mechanical interlocking on contact opening and contact status are analyzed

Read more

Summary

Introduction

The use of total hip replacement (THR) prosthesis has become the second most performed surgical procedure every year, it aims to replace the defective natural articulation [1]. The main reason to proceed to this operation is to attenuate the hip pain. Implants in (THR) can be fixed by either cement or cementless methods in the patient's bones. In both procedures, the stability of the prosthesis in the hosted bone plays an important role in the long-term durability of the operation [2, 3]. Finite element analysis, biomaterials, bone-cement interface, damage

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.