Abstract

AbstractEarthquake-induced damage to structural components and spray-applied fire-resistive material (SFRM) in steel gravity frame beam-column connection regions can impact connection performance during an ensuing fire. Bolted connections are particularly susceptible to failure at elevated temperatures due to a rapid loss in bolt capacity with increasing temperature, which occurs at an accelerated rate compared to the thermal degradation of structural steel. In order to characterize structural and SFRM damage over a range of seismic drift demands, two large-scale SFRM insulated beam-column connection assemblies utilizing single-plate and unstiffened seated connection designs, with composite floor slabs, were tested under combined gravity and lateral loading. SFRM cracking, debonding, and spalling were observed during both tests, exposing critical connection elements. In addition, the single-plate connection assembly, which was developed in accordance with U.S. national guidelines but contained design feat...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.