Abstract
The open-winding permanent-magnet synchronous generator (PMSG) fed by a semicontrolled converter is a promising configuration due to lower expense, simplified driving circuit, and reliable operation capability. When supplied by a common dc bus, the open-winding PMSG system can be more simplified. Because the voltage output by the diode converter is decided by the three-phase current polarity, the available voltage vector modulation range of the voltage source converter is limited. As a result, the current zero-crossing duration behavior is determined by the power factor angle, which will lead to zero-crossing voltage pulse disturbance, serious electromagnetic interference, and unexpected diode switching loss. This paper aims to reduce the current zero-crossing duration by injecting the third harmonic current into the zero-sequence current. A proportional resonant regulator is proposed to control the zero-sequence current. Finally, the proposed method is validated in a 1-kW semicontrolled open-winding PMSG experimental system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.