Abstract

ObjectivesA radiographic study was designed to measure the relationship of the exiting nerve root and its surroundings to the corresponding intervertebral disc for percutaneous transforaminal endoscopic lumbar interbody fusion to better understand the regional anatomy and to improve clinical applications.MethodsA retrospective study from January 2017 to October 2017 was conducted at Tianjin Hospital. CT images were obtained from patients presenting low back pain (110 patients), and analysis was performed bilaterally from L2‐3 to L5S1. In the rotating coronal plane we analyzed: the nerve root–dural sac distance at the superior and inferior margins of the disc (Js, Ji); the nerve root–pedicle distance at the medial, middle, and lateral borders of the pedicle (Pa, Pb, Pc); the pedicle width (W); and the safe working zone, defined as a trapezoid bounded by the inferior pedicle and the exiting nerve root (S). In the transverse plane, the nerve root‐articular process and the shortest distance for the nerve root‐articular process joint surface were analyzed at the superior and inferior margins of the disc (Gs, Gi), respectively. The groups were analyzed using ANOVA, and paired t‐tests were used to compare the left and right sides.ResultsFrom L2‐3 to L5S1, the distance of the nerve root to the dural sac was larger at the inferior margin of the disc. From L2‐3 to L5S1, each segment of the vertebral nerve root‐pedicle distance gradually decreased from medial to lateral. From L2‐3 to L5S1, the distance from the exiting nerve root to the middle and lateral margins of the pedicle gradually decreased, with L5S1 being the minimum. Some significant differences were observed between the left and right sides for L4‐5 and L5S1. The pedicle width of the vertebral body and the mean area for the safe working zone gradually increased from L2‐3 to L5S1. In the axial plane, the shortest distance between the nerve root and articular process joint surface at the inferior margin of the disc was greater than the distance for the nerve root to the articular process at the superior margin of the disc from L2‐3 to L5S1. There were no significant differences between the two sides.ConclusionsIt is more difficult to implant a cage with a width of 10 mm above the L3‐4 level. By removing part of the superior articular process, the safe working area can be expanded, and damage to the nerve or other structures can be avoided when implanting a cage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.