Abstract
Abstract The charge collection efficiency (CCE) of silicon detectors, previously irradiated with high neutron fluences, has been measured at 4.2, 77 and 195 K. The CCE recovery measured after 1.2×10 14 n / cm 2 is 100% at a bias voltage of 50 V. For 2×10 15 n / cm 2 the most probable signal collected for minimum ionising particles is 13 000 electrons, corresponding to 50% CCE, at a bias voltage of 250 V. Negligible difference has been observed between 77 and 4.2 K operation, while no recovery was measurable at 195 K. The timing of the signal was measured to be better than 5 ns. The samples were irradiated and stored at room temperature and cooled only when operated. Reproducible results were obtained after several weeks and several thermal cycles.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.