Abstract

Today all advanced neutron facilities maintain a fleet of Orange cryostats, or similar systems, to provide low temperature sample environment in neutron scattering experiments. However recent liquid helium cost increases, caused by global helium supply problems, have raised significant concern about the affordability of such cryostats. The ISIS facility is carrying out a development programme intended to substitute conventional cryostats with cryogen-free systems preferably based on pulse tube refrigerators. The main aim of the development is to create a cryogen-free system as a potential replacement for the conventional Orange cryostat. This paper describes the design and test results of a cryogen-free cryostat, based on a pulse tube refrigerator, with 50 mm diameter top-loading sample facilities for neutron scattering experiments. The sample temperature range is 1.45–300 K in the continuous flow regime. The cryostat may also be used with ultra-low temperature dilution refrigerator inserts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.