Abstract

Faster write signal rise-times and the introduction of recording head technologies that are more susceptible to electrical overstress damage have made crosstalk an issue of concern in rigid disk drives. Crosstalk reduction efforts often focus on the physical routing of the suspension interconnect, but there are system-level practices that can have profound impacts on reducing crosstalk. This paper discusses a time-domain crosstalk measurement method, the effect of common impedance coupling at the system level, a conceptual model for estimating crosstalk, suspension interconnect crosstalk reduction techniques, and the effectiveness of the reduction techniques.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.