Abstract

Considering the different Poisson's ratios of subsoil, this paper derived the calculating formula for the critical edge load under the strip foundation, analyzed and discussed the steps of the calculating formula, carried out the maximum depth for the plastic zone reached and bearing capacity factors. With various Poisson's ratio of subsoil, the bearing capacity factors are dependent on internal friction angle and Poisson's ratio. On the case of the constant friction angle, the bearing capacity factors' values and bearing capacity increase with the increasing of Poisson's ratio. Compared with the engineering examples, it demonstrated the accuracy and reasonableness of the presented calculation approach.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.