Abstract

The heated band width is the most important processing parameter for local postweld heat treatment of tubes and pipes.A correct heated band width must be chosen so that the allowable maximum temperature difference in the soak band is maintained and a sufficient degree of stress relaxation is achieved.In this paper, the effects of the geometrical and the thermal parameters in the postweld heat treatment are investigated using axisymmetric FEM.The most severe condition in which the heat input and insulation are only applied to the outside surface of the pipe has been studied in detail. The effect of the geometrical and the thermal parameters on the through thickness temperature gradients is investigated.Through this study, it is found that the required heated band width is mainly influenced by the wall thickness and the heat transfer coefficient on the internal surface.The computed results show that the Hi number is inadequate for practical use under general conditions.A more general Hi number is proposed as a linear function of the thickness. Further, based on the computed results, the authors propose criteria for the heated band width which includes the effect of the geometrical and the thermal parameters.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.