Abstract

Abstract ASTM Committee E-24 on Fracture has recently standardized the crack tip opening displacement (CTOD) measurement method. Three major differences between the ASTM E 1290-89 method and British Standard BS5762:1979 are outlined, and the influence of these differences on the critical crack initiation CTOD value is studied. The study is based on a typical fatigue crack and slow crack growth front profile. A difference of up to 6% in the CTOD values between the two standards, irrespective of the slow crack growth size, was found in the present study. However, a marginal ditterence of only 2% in the initiation CTOD value could be observed for the slow crack growth situation considered.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.