Abstract

Low-cycle fatigue tests have been carried out on an annealed commercially pure titanium under strain-controlled conditions with constant strain range. The initiation of fatigue cracks was observed successively with the aid of an optical microscope using the replication technique and microstructural deformations were measured. Results show that fatigue crack initiation was predominantly intergranular ; however, slip band cracks often appeared also in the low strain range. At the specified grain boundaries, irreversible steps attributed to a few slip systems formed under each strain cycle. The accumulation of irreversible steps due to strain cycling is thought to cause intergranular cracking.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.