Abstract

ABSTRACT The metal magnetic memory is used to detect the micro damage of structure based on the SMFL (self-magnetic flux leakage) effect, but it lacks an effective comprehensive diagnosis index suitable for the ferromagnetic material. In this paper, steel strand specimens were tensioned at different force levels, and the experimental study on the corrosion detection was carried out. Besides the monitoring analysis of the cable force, the initial structural magnetic field ΔBx 0 and the surface SMFL signals Bx (α) induced by corrosion were both analysed. The results show that ΔBx 0 curves of steel strand material present the periodic fluctuation. Considering ΔBx 0 and measuring distance z, the proposed dimensionless damage analysis index X can be used for the quantitative research of corrosion diagnosis. The small influence of the cable force on index X is also illustrated. Moreover, the strong correlation that exists between the average maximum index and the corrosion ratio α is well fitted by the three-order polynomial curves.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.