TiNi shape memory alloy has been modified by Ta plasma immersion ion implantation technology to improve corrosion resistance. The results of the polarization tests show that the corrosion resistance of TiNi alloy in Ringer's solution at 310 K has been improved by the Ta ion implantation and the Ta/TiNi sample with a moderate incident dose of 1.5 × 10 17 ions/cm 2 exhibits the best corrosion resistance ability. The surface characterization and chemical composition of the Ta/TiNi samples were determined by Auger electron spectroscopy (AES), Atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) methods. AFM images reveal that compact aggregates of nano-grains uniformly disperse on the surface of the Ta/TiNi samples. AES and XPS analyses on the Ta/TiNi sample show that the component of the surface layer is mainly composed of TiO 2 and Ta 2O 5, which is benefit to the corrosion resistance ability and biocompatibility.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.