Abstract

The present paper deals with the pressure containment and deformation capacity of corroded high-grade steel line pipe. Firstly, some well established models are investigated concerning their predictive accuracy if applied to high-grade line pipe steel. In particular, it will be shown that all models under consideration tend to overestimate the remaining strength in the case of high-grade steel pipes. Afterwards, FE-analyses are performed in order to study the local evolution of plastic flow in the area of the corrosion defect; at the same time, the burst pressure is predicted applying von Mises plasticity and a simple failure criterion. Although different defect geometries are associated with well pronounced differences in the evolution of the plastic flow around the corrosion defect no significant effect on the burst pressure is found. Finally, the main results of a hydrostatic burst test performed on a pristine X100 line pipe joint are presented. It appears that the material under consideration seems to have anisotropic plastic material properties which may have effect on burst pressure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.