Abstract

This paper analyzed the morphology and reasons of pitting corrosion perforation of 0Cr18Ni9 stainless steel cooling water pipes in a power plant and pointed out the measures to prevent the pitting corrosion under this condition. The results showed that: the reason of pitting corrosion of 0Cr18Ni9 stainless steel cooling water pipes was the existence of multiple Cl-and easily fouling Ca2+ and Mg2+ in water, with the corrosion products mainly the oxides of Fe and Cr; the economic measures to prevent pitting corrosion were to increase the pH of water and decrease the content of Ca2+ and Mg2+.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.