Four extracorporeal perfusion conditions (continuous beating, continous fibrillating, pulsatile beating, and pulsatile fibrillating) were tested for 15 minutes each in pigs. Coronary flow, endocardial-epicardial flow ratio, phasic coronary flow, myocardial oxygen consumption, and myocardial lactate extraction were measured. No significant differences in any of these variables were found between pulsatile and continuous flow states in either fibrillating or beating hearts ( p > 0.05). In both fibrillating conditions, significant elevations of myocardial oxygen comsumption and decreases in endocardial-epicardial flow ratios were found ( p < 0.05). Lactate extraction occurred in all conditions, and phasic coronary flows were similar in both beating conditions. These data suggest caution in the expectation that pulsatile perfusion will reverse the coronary flow and myocardial oxygen consumption changes seen with fibrillation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.