Investigations of noninvasive prenatal screening for aneuploidy by analysis of circulating cell-free DNA (cfDNA) have shown high sensitivity and specificity in both high-risk and low-risk cohorts. However, the overall low incidence of aneuploidy limits the positive predictive value of these tests. Currently, the causes of false positive results are poorly understood. We investigated four pregnancies with discordant prenatal test results and found in two cases that maternal duplications on chromosome 18 were the likely cause of the discordant results. Modeling based on population-level copy-number variation supports the possibility that some false positive results of noninvasive prenatal screening may be attributable to large maternal copy-number variants. (Funded by the National Institutes of Health and others.)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.