Abstract

This paper proposes a control scheme for the wide operation range of an induction generator (IG) with a Vienna rectifier. A Vienna rectifier has the limited operation range because the sign of the current should be the same as that of the voltage in the normal operation. For this reason, the power factor of a Vienna rectifier is also limited. In the IG, the d-axis stator current is necessary for the self-excitation of the IG. Usually, the d-axis stator current is controlled to the rated d-axis current, which means that IG can operate in the low power factor. Therefore, the operation range of the IG with a Vienna rectifier is narrow. The proposed control method adjusts the d-axis current appropriately to extend the operation range and to include the operating power factor in the feasible operation range of a Vienna rectifier. The analysis results of the proposed method are verified from PSIM simulations with a 150-kW IG system using a Vienna rectifier.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.