Abstract

Most of the previous research on flash gas bypass (FGB) focused on performance improvement in steady state and demonstrated that compared to direct expansion mode (DX), FGB mode have better performance. However, the control strategy of flash gas bypass system and dynamic behavior during start-ups and transients were not yet clearly defined and investigated. In this paper, a novel control strategy has been proposed for an automobile air conditioning system operating in flash gas bypass mode with R134a as the refrigerant. The proposed control strategy utilized an electronic expansion valve (EV) for the control of subcooling from condenser outlet and a bypass valve (BV) for superheat from compressor inlet. Both start-up and transient system behaviors were studied. The experimental results showed that the proposed cycle control strategy was found to be able to provide reliable control to the system. In addition, proper sizing of bypass valve and flash gas bypass tank have also been studied.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.