Water sterilization at sterility assurance levels exceeding 10−6 has been achieved with a novel high temperature and pressure sterilization system (HAPSS) capable of continuous-flow sterilization. The tested sterilizer produces >2,000 L/day and does not require filters, moving parts, or regular maintenance and can operate for multiple years with only water and standard voltage/amperage electricity. Sterility assurance levels were determined using Geobacillus stearothermophilus spores with inactivation experiments as a function of temperature and flow rate (i.e., duration/dosage at given temperature). Sterility of 1.0 × 104 CFU/mL G. stearothermophilus spore suspensions was achieved at the highest water flow rate of 1.4 L/min at 140 and 130 °C. The low cost and maintenance-free operation of HAPSS is envisioned to impact water sterilization needs of developing nations, hospitals, and commercial point of use applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.