Abstract
A calibration and monitoring system for the Harp experiment scintillator-based time of flight system has been developed, by using an Nd-YAG laser with passive Q-switch and active/passive mode-locking and a custom made laser light injection system based on it bundle of IR monomode optical fibers. For the laser pulse timing a novel ultrafast InGaAs MSM photodiode, with 30 ps risetime, has been used. Experience over a several months data taking period in 2001 and 2002 shows that drifts in timing down to about 70 ps can be traced.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.