Abstract

A high temperature split Hopkinson pressure bar (SHPB) test system is used to investigate the effects of temperature as well as those of strain and strain-rate. Effects of temperature for the vanadium alloy (V-5Cr-5Ti) are investigated by developing a high temperature SHPB test system. In this work, high temperatures greater than 1100°C are attained in the SHPB test specimens by using a synchronically assembled heating system .When testing with the high-temperature SHPB apparatus, care is required to prevent oxidation of the surface of the specimen, and to prevent an inhomogeneous temperature distribution from developing in the specimen. To determine the true flow stress–true strain relationship, specimens are tested from 15°C to 1100°C and at a strain-rate of about 3000 s-1: The parameters for a Johnson–Cook constitutive equation is determined from the test results. The Johnson–Cook constitutive equation is suitable for expressing the dynamic behavior of the V-5Cr-5Ti vanadium alloy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.