Abstract

Constant-step stress accelerated life test of Vacuum Fluorescent Display (VFD) was conducted with increased cathode temperature. Statistical analysis was done by applying Weibull distribution for describing the life, and Least Square Method (LSM) for estimating Weibull parameters. Self-designed special software was used to predict the VFD life. Numerical results showed that the average life of VFD is over 30000 h that the VFD life follows Weibull distribution, and that the life-stress relationship satisfies linear Arrhenius equation completely. Accurate calculation of the key parameter enabled rapid estimation of VFD life.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.