Abstract

The method was specifically developed for the determination and confirmation of streptomycin in apple samples using the whole mellow apple. The method is simple, rapid, sensitive and was validated for streptomycin in accordance with SANCO/3131/2007. After extraction with phosphate buffer and a pH change, the clean-up was performed by the way of SPE with polymeric phase. The LC–MS/MS analysis was carried out using a HILIC column for the separation of the analytes and a triple quadrupole mass spectrometer in positive ESI mode to measure the transitions of the substances in MRM mode. For the quantification of streptomycin a matrix calibration curve in the linear range of 1.0–20 μg kg −1 and the internal standard dihydrostreptomycin (10 μg kg −1) were used. The calculated validation parameters like the recovery (101–105%) for 2, 5, 10 and 20 μg kg −1 and the relative standard deviation (RSD, 4.1–11.4%) of the 6 replicates fulfil the requirements of SANCO/3131/2007. The LOQ was determined as 2 μg kg −1.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.