Two concrete deck slabs extracted from a Canadian bridge have been evaluated using non-destructive testing (NDT), followed by destructive testing. Throughout its service life, the bridge experienced harsh environmental conditions with frequent freeze-thaw cycles, hot and humid summers, and the use of de-icing salts during winters. This study presents the preliminary results of an exhaustive condition assessment of two prestressed concrete slab panels, where NDT techniques (visual assessments, electrochemical and concrete soundness tests) have been conducted prior to destructive testing. Although visual inspection did not indicate poor concrete quality, the results of the ultrasonic pulse velocity testing showed that both concrete slabs are of poor quality and may be suffering from internal defects. Chlorides may have also been introduced through the strand conduit anchor points. These findings raise concerns regarding the structural integrity of corrosion-affected members.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.