Abstract
For the estimation of some co-administered antimicrobials, two highly accurate and precise spectrofluorimetric methods were developed. Fluconazole (FLZ) is co-administered with either ciprofloxacin (CPR) or ofloxacin (OFX) for the treatment of certain microbial infections. On the other hand, another antimicrobial drug, vancomycin (VNC) is co-administered with ciprofloxacin (CPR) for peritonitis treatment. In method I, conventional spectrofluorimetry has been introduced for the concurrent quantitative estimation of FLZ in presence of OFX or CPR. While in method II, a first derivative synchronous spectrofluorimetric technique was adapted for quantitation of VNC and CPR co-administered combination. Both of them were utilized for estimation of the considered drugs in raw materials, laboratory prepared mixtures, dosage forms, and biological fluids. Method I was relied on simultaneous measuring of the native fluorescence of FLZ and OFX or CPR without any overlapping between the emission spectra of each binary mixture (FLZ / OFX) and (FLZ / CPR). Fluorescence intensities were measured at 283.0, 483.0 and 436.0 nm after excitation at 262.0, 292.0 and 275.0 nm for FLZ, OFX and CPR, respectively. Method II was utilized the synchronous fluorescence intensity of VNC and CPR in methanol at Δλ = 40 nm. The first derivative synchronous spectra were calibrated at 297.0 nm for VNC and at 379.5 nm for CPR. Different variables influencing conventional and synchronous fluorescence intensities of the four antimicrobials under investigation were precisely optimized. Both methods were successfully investigated for the determination of the studied drugs in plasma. The linear data analysis for the calibration curves reveals a good relationship in the ranges of 1.0–10.0, 0.25–2.5 and 0.06–0.6 μg/mL for FLZ, OFX and CPR for method I with limits of detection 0.144, 0.038 and 0.007 μg/mL and limits of quantitation of 0.437, 0.114 and 0.021 μg/mL for FLZ, OFX and CPR, respectively. Linearity range for method II was 0.5 –10.0 μg/mL for VNC and CPR with detection limits of 0.127 and 0.110 μg/mL and quantitation limits of 0.380 and 0.334 μg/mL for VNC and CPR, respectively. International Council on Harmonization ICH Q2 (R1) Guidelines were followed in the developed methods validation. The achieved outcomes were statistically compared with those found by the reported ones, and no significant difference was observed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.