Abstract

This paper evaluates the behavior of the Cazaly hanger under vertical load and proposes an additional design requirement for the connection. In 1965, Canadian PCI instigated a research program to evaluate the behavior of the hanger, which led to the shear-friction design basis for the hanger in the third edition of the PCI Design Handbook: Precast and Prestressed Concrete. Current tests show that in shallow sections the hanger does not follow shear-friction behavior but instead behaves more closely to a concrete-breakout model. Reassessment of the 1965 specimens revealed shear-friction to be a poor predictor of capacity in shallow sections, while the concrete-breakout models provide conservative predictions. A proposed revision to the sixth edition of the PCI Design Handbook based on concrete-breakout capacity is recommended for Cazaly hanger design method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.