Abstract

The aim of study was to compare the sensitivity of MRI and CTA for endoleak detection and classification after EVAR. Twenty-eight patients, between 2 days and 65 months after EVAR, were evaluated with both CT and MRI. Twenty-five patients had an Ancure graft and the other three had an Excluder. The MRI protocol for endoleak evaluation included: a T1-weighted spin echo, a high-resolution 3D CE-MRA, and a post-contrast T1-weighted spin echo. In total 40 ml Gadolinium was administered. The CT protocol consisted of a blank survey followed by a spiral CT angiography (CTA) using 140 ml of Ultravist. An experienced, blinded observer evaluated all CTs and MRIs. Using MRI and MRA techniques significantly more endoleaks (23/35) were detected than with CTA (11/35) (p=0.01, Chi-Square). CT could not determine the type of endoleak in 3 of the 11 endoleaks detected and was uncertain in one. MRI was uncertain about the type in 14 of the 23 endoleaks detected. All endoleaks visible on CT were visible by MRI as well. MRI techniques are more sensitive for the detection of endoleak after endovascular AAA repair than CT.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.