The compression factors and vapor pressures have been measured on bromotrifluoromethane using a Burnett apparatus. The results on the compression factor cover the range of temperatures 263 to 393 K and of pressures 0.14 to 11.6 MPa, corresponding to a density variation from 7 to 1367 kg· m−3. The experimental uncertainty of these 176 measurements of compression factor was estimated to be 0.2%. Thirty measurements of vapor pressure were made for temperatures 245 to 339 K, with an experimental uncertainty of 0.1%. Based on these results, the second virial coefficients were determined for temperatures 293 to 393 K.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.