Abstract
Composite wiring techniques using various configurations of Kirschner pins and stainless steel wire sutures have been applied to the treatment of 63 fractures of the long bones of the hand. The secure fixation achieved allowed active motion within 1 week of operation. Thirty-three metacarpal fractures achieved a final mean total active motion of 256 degrees (standard deviation 13.4) (normal total active motion −260 degrees). Twenty-one phalangeal fractures achieved a mean total active motion of 215 degrees (standard deviation, 46 degrees). There were no instances of infection, malunion, nonunion, loss of reduction, or tendon rupture in the 63 fractures that were treated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.