Abstract

BackgroundA successful clinical outcome for total hip arthroplasty (THA) depends on accurate sizing and positioning of the implants. Using three-dimensional (3-D) pre-operative planning with a computerized tomography (CT) scan has many potential advantages over conventional 2-D planning using radiographs, including potentially more accurate assessments of the size and anteversion of the acetabulum, as well as lateral femoral offset. The purpose of this study was to compare the accuracy of 3-D to 2-D templating with respect to acetabular and femoral size, as well as lateral femoral offset. MethodsPre-operative templating data was collected prospectively from a consecutive series of 290 primary THAs (acetabulum on all, femoral component on 255 of the cases using one specific stem). All cases were initially templated on a digital imaging picture archiving and communication (PACS) system with calibrated images to estimate the acetabular size, femoral size, and lateral femoral offset. The 3-D templating was then performed with software based on a CT scan, and the results were compared to what was surgically implanted. ResultsThe 3-D templating for the acetabulum was accurate 99.7% of the time based on the final implanted component. The 2-D templating for the acetabulum was accurate 39% of the time, with 46% templating larger and 15% templating smaller than the final implanted component. The 3-D templating of the femoral component was accurate 63% of the time, and within one size of final implant in 96% of cases. The 2-D templating of the femoral component was accurate 53% of the time and within one size of final implant in 94% of cases. Lateral femoral offset consistently matched the 3-D plan, with a 100% match rate. The 2-D templated femoral offset was accurate 87% of the time and was changed in 13% of cases after 3-D templating. ConclusionThe CT-based 3-D preoperative planning was superior to 2-D planning for THA with respect to acetabular size, femoral size, and lateral femoral offset. Precise acetabular component sizing conserves bone and allows for a more predictable press fit, while facilitating efficient inventory management. Lateral femoral offset is often difficult to measure on 2-D images, and 3-D templating consistently allows for accurate offset restoration, which is important for normal hip function and stability.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.