Abstract
OBJECTIVE To compare the registration accuracy of three-dimensional (3D) facial scans for the design of full-arch implant supported restoration by five methods and to explore the suitable registration method. METHODS According to the criteria, ten patients with maxillary edentulous jaw or end-stage dentition requiring implant supported restorations were enrolled in this study. A special rim with individual feature marks reflected appropriate occlusal relationship and esthetic characteristics was made for each patient. Both 3D facial scan data of natural laughter and with opener traction to expose the teeth or occlusal rim of each patient were acquired by facial scan and input to the digital analysis software Geomagic Qualify 2012. The dataset was superimposed by five different methods: seven facial anatomical landmark points alignment, facial immobile area alignment (forehead and nasal area), facial anatomical landmark points and immobile area combining alignment, facial feature points alignment, facial and intraoral feature points alignment with the same local coordinate system. The three-dimensional deviation of the same selected area was calculated, the smaller the deviation, the higher the registration accuracy. The 3D deviation was compared among the three registration methods of facial anatomical landmark points, facial immobile area alignment and the combination of the above two methods. Friedman test was performed to analyze the difference among the three methods (α=0.05). The effect of the aid of the facial and intraoral feature points were evaluated. Paired t test were performed to analyze the difference (P<0.05). RESULTS The average three-dimensional deviation of the selected area after alignment with the facial anatomical landmarks was (1.501 2±0.406 1) mm, significantly larger than that of the facial immobile area best-fit alignment [(0.629 1±0.150 6) mm] and the combination of the two methods[(0.629 1±0.150 6) mm] (P < 0.001). The aid of the facial feature points could significantly reduce the deviation (t=1.001 3, P < 0.001). There was no significant statistical difference in the remaining groups. CONCLUSION The forehead area of the 3D facial scan can be exposed as much as possible. The establishment of facial characteristic landmark points and the use of the invariant area alignment can improve the accuracy of registration. It should be clinically feasible to apply three-dimensional facial scan to the design of full-arch implant supported restoration with the registration of the immobile area on the face especially the forehead area.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.