Abstract

Statement of Problem. The fracture strength of a number of new ceromer systems for the fabrication of anterior fixed partial dentures is unknown. Purpose. The purpose of this study was to compare the fracture strengths of metal-ceramic crowns and 3 types of ceromer crowns in a simulated anterior tooth preparation. Material and Methods. A resin maxillary central incisor analog was prepared with a 5-degree convergence angle and a 90-degree, 1-mm shoulder. The incisal edge was reduced by 2 mm, and the axiogingival and axioincisal line angles were rounded. A mold of this tooth was made with vinyl polysiloxane impression material. Ten wax patterns were made from the mold and cast in a nickel-chromium alloy for the fabrication of metal dies, from which 10 metal-ceramic crowns were fabricated. Ten crowns for each of 3 ceromer systems (Artglass, Sculpture, and Targis) were fabricated from the same metal die. Each crown group was prepared, polymerized, air-particle abraded, and finished in accordance with the specific manufacturer's instructions. All 4 types of finished crowns were luted to the dies and embedded in polymethyl methacrylate resin blocks. Their fracture resistance was tested in a universal testing machine. The load was directed at the incisolingual line angle, at 130 degrees to the long axis of each specimen, until catastrophic failure occurred. A 7-mm-diameter rod was used to load the artificial crowns, with the center of the rod in contact with the crown surfaces. Analysis of variance and Tukey's multiple comparisons test (P<.05) were applied to the data. Results. Metal-ceramic crowns fractured at significantly higher values than ceromer crowns (1317 vs 602 N, respectively) (P<.05). No significant difference was found among the fracture values of Artglass, Sculpture, and Targis crowns. Conclusion. Within the limitations of this study, failure load values for the 3 ceromer crowns tested, although significantly lower than the values for metal-ceramic crowns, still exceeded normal occlusal forces. (J Prosthet Dent 2002;88:170-5.)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.