Abstract

The article presents the measurement results of the relaxation of long-term loaded compression springs manufactured out of non-alloy steel. The goal was to determine the differences between the interrupted and uninterrupted tests. During the relaxation test that lasted 5000 hr in a laboratory with a temperature of 22ºC, initial shear stress set at a value of 30% of the ultimate tensile strength of the material, decreased the strength of the springs with a wire diameter of 1 mm by 3.6%, springs with a wire diameter of 3.15 mm by 2.5%, and springs with a wire diameter of 5 mm by 1.3%. The difference in the results was found in tests 16 times and 4 times interrupted to measure the current relaxation. The results of intermittent tests cannot be considered as relaxation values for statically loaded springs. Conversely, when determining the maximum tension of quasi-statically loaded springs with respect to the relaxation, the uninterrupted relaxation tests cannot be used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.