Abstract
Choosing an inappropriate method of sample collection can often have a detrimental impact on DNA recovery. Multiple studies highlight the importance of selecting the recovery method based on the type of surface the DNA sample is located on. This study aimed to investigate the efficacy of sample collection via the single cotton swabbing method in comparison to recovery directly from the material cut from the surface. The three types of surfaces included cotton, paper, and cardboard. DNA sources comprised cell-free and cellular DNA, as well as blood and saliva as examples of body fluids commonly encountered at crime scenes. The data analysis revealed that the cutting-out method resulted in higher DNA recovery from all but cardboard surfaces, making it the more efficient collection method. Despite its limitations, the cutting-out method should be considered as the DNA recovery method of choice when suitable.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.