Abstract
IntroductionIn Japan, patient-led insulin titration is rare in type 2 diabetes mellitus (T2DM) patients. Few studies have compared the effects of patient-led versus physician-led insulin titration on patient-reported outcomes in Japanese T2DM patients. This study aimed to compare the effects of patient-led and physician-led insulin titration in Japanese insulin-naïve T2DM patients on safety, glycemic control, and patient-reported outcomes (emotional distress, treatment satisfaction, and self-efficacy).MethodsUltimately, 125 insulin-naïve Japanese T2DM patients were randomly assigned to either a patient-led insulin self-titration group or a physician-led insulin titration group and monitored for 24 weeks. The primary endpoint was a change in emotional distress as measured using the Problem Areas in Diabetes scale (PAID). Secondary endpoints included treatment satisfaction, as measured with the Diabetes Treatment Satisfaction Questionnaire (DTSQ), self-efficacy as measured using the Insulin Therapy Self-Efficacy Scale (ITSS), glycated hemoglobin (HbA1c) levels, fasting plasma glucose levels, body weight, insulin daily dose, and frequency of hypoglycemia.ResultsThere was no significant difference between the groups in PAID and DTSQ scores. The results for the primary endpoint should be interpreted taking account that the sample size for the power calculation was not reached. ITSS scores were significantly higher in the patient-led self-titration group. HbA1c and fasting plasma glucose levels were significantly decreased in both groups, but the decrease was significantly larger in the patient-led self-titration group. Although the insulin daily dose was significantly higher in the patient-led self-titration group, severe hypoglycemia did not occur in either group, and the frequency of hypoglycemia was similar in both groups.ConclusionSelf-measurement of blood glucose and self-titration of insulin enhanced the patients’ self-efficacy without compromising their emotional distress or treatment satisfaction. Also, insulin self-titration was found to be safe and effective; it resulted in better glycemic control without severe hypoglycemia.Trial registrationUniversity Hospital Medical Information Network Clinical Trials Registry (UMIN-CTR) (registration number: UMIN000020316).Supplementary InformationThe online version contains supplementary material available at 10.1007/s13300-020-00995-8.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Diabetes therapy : research, treatment and education of diabetes and related disorders
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.