Abstract
ABSTRACT This study aims to analyze sodium azide removal from medical laboratory wastewater by using Electro-Fenton (EF) and ozonation methods and to determine the optimum process conditions. Under optimum conditions; 98.9% and 99.6% sodium azide removal efficiency was obtained through EF and ozonation processes, respectively. This is the first and the only optimization study in literature in which response surface methodology and central composite design were used for sodium azide removal from wastewater. Results of the study indicated that EF and ozonation processes are effective methods for sodium azide removal, and central composite design is a suitable tool for process optimization.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.