Abstract

The objective of this paper is to compare fatigue crack closure loads obtained by various crack opening displacement methods. Crack closure loads are obtained by three different techniques: optical interferometry, backface strain measurements, and crack mouth opening displacement (CMOD) gage measurements. Optical interferometry gives complete through-the-thickness variation of crack closure, while backface strain and CMOD measurements provide an average (bulk) crack opening load for the entire specimen thickness. The present paper focuses on comparing the bulk specimen measurements of crack opening load with point measurements obtained at various points along the crack front from the interferometry method. It was observed that the closure loads obtained from backface strain measurements agree well with the CMOD closure values, although the interferometric crack opening loads are higher than either compliance techniques.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.