Abstract

Micromovements of the implant-abutment connection influence peri-implant bone preservation. The maximal torque after a cycle of implant prosthetic screw tightening using original components of different manufacturers and replicas produced by other companies is evaluated and quantified in this study. A total of 30 Mis Seven® standard platform implants and 30 interfaces were used, and 30 standard platform screws were tested, 10 Mis®, 10 Iconekt®, and 10 Exaktus®. The screws were tightened with an MIS® torquemeter until their respective fracture, and the fracture point was measured through the equipment's load cell, CS-Dental Testing Machine®. The screws were analyzed under an Olympus® SZ61 microscope. The fracture points were recorded and compared among all samples. To compare the mean values of the fracture torques, t-tests were performed using the reference values associated with each brand and the sample results. The variable “Place of Fracture” between the original Mis® brand and the Exaktus® replica compared to the Iconekt® replica presented a statistically significant difference (p < 0.001). When analyzing the variable “Fracture Torque,” although it was verified that the replica screws (Iconekt® and Exaktus®) had a lower maximum torque, 65.11 Nm and 62.89 Nm, respectively, compared to the original Mis® brand (70 Nm and 69 Nm), there were no statistically significant differences p > 0.05. Nonoriginal screws did not present different fracture resistances compared to the original Mis® brand screws. The fracture site of Iconekt® screws showed a different pattern compared to the other brands.

Highlights

  • ® Exaktus replica compared to the Iconekt replica presented a statistically significant difference (p < 0.001)

  • When analyzing the ® ® variable “Fracture Torque,” it was verified that the replica screws (Iconekt and Exaktus ) had a lower maximum torque, ® ® 65.11 Nm and 62.89 Nm, respectively, compared to the original Mis brand (70 Nm and 69 Nm), there were no statistically ® significant differences p > 0.05

  • Nonoriginal screws did not present different fracture resistances compared to the original Mis ® ® brand screws. e fracture site of Iconekt screws showed a different pattern compared to the other brands

Read more

Summary

Introduction

® Exaktus replica compared to the Iconekt replica presented a statistically significant difference (p < 0.001). When analyzing the ® ® variable “Fracture Torque,” it was verified that the replica screws (Iconekt and Exaktus ) had a lower maximum torque, ® ® 65.11 Nm and 62.89 Nm, respectively, compared to the original Mis brand (70 Nm and 69 Nm), there were no statistically ® significant differences p > 0.05. E fracture site of Iconekt screws showed a different pattern compared to the other brands. Regardless of the tolerance between the interface/implant parts, the screw and the level of torque used play an important role in the stability of the union when subjected to cyclical loads. E greater the torque applied to the retaining screw and prosthetic interface, the smaller the micromovement between the parts [7, 8] Regardless of the tolerance between the interface/implant parts, the screw and the level of torque used play an important role in the stability of the union when subjected to cyclical loads. e greater the torque applied to the retaining screw and prosthetic interface, the smaller the micromovement between the parts [7, 8]

Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.