Abstract

ObjectivesA prospective, blinded, randomized trial was performed to evaluate the incidence rates of external ventricular drainage (EVD)-related infection (ERI) after tunneled EVD (T-EVD) and standard EVD (S-EVD). Patients and methodsFrom February 2018 to February 2019, all adult patients admitted to the Union Hospital Neurosurgery Center for EVD placement were eligible for inclusion. After the application of strict exclusion criteria, all enrolled patients were randomly divided into two groups. The patients in Group A received S-EVD, and the remaining patients in Group B received T-EVD. A linear incision was made for T-EVD. The distal end of the catheter was inserted approximately 5 cm until cerebrospinal fluid was readily obtained, and then the catheter was tunneled approximately 4–5 cm from the insertion point. Finally, an external CSF drainage system was connected to the catheter. For the S-EVD patients, we secured the catheter at the original incision site after insertion, and an external CSF drainage system was also connected to the catheter. The rates of ERI were compared between the two patient groups. The odds ratios and χ² test were used to analyze the results. ResultsOne hundred twenty patients were randomly divided into two groups and underwent EVD placement. Among them, 60 patients in Group A received S-EVD, and 60 patients in Group B received T-EVD. Finally, 51 patients in Group A and 50 patients in Group B met all of the study inclusion/exclusion criteria and were thus eligible for inclusion in the evaluation of ERI rates. All clinical features of the two groups were similar. A total of 12 patients’ (11.9%) CSF cultures were positive for infection. Ten (19.6%) patients who underwent S-EVD had CSF-positive cultures, while only 2 (4.0%) patients who underwent T-EVD had CSF-positive cultures (P = 0.034). Additionally, 8 patients in Group A and 1 patient in Group B were complicated with CSF leakage (P = 0.039). ConclusionsCompared to S-EVD, T-EVD, when performed according to a previously established perioperative management protocol, resulted in lower infection and CSF leakage rates. We recommend that T-EVD should be preferentially performed when surgeons determine whether a catheter can be removed within 10 days, and the catheter used for EVD should be removed as soon as permitted by the clinical circumstances.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.