Abstract
This article compares the characteristics of a dual three-phase synchronous motor under different operating conditions such as healthy, half-control, and postfault conditions. The inductances are analyzed to confirm the interaction between two three-phase systems, and induced voltages of each phase are measured to verify the interaction behaviors. The postfault characteristics are analyzed under open-circuit faults (single-open-switch and single-open-phase faults) and short-circuit faults (single-short-switch and one-three-phase-short faults). The predicted results are validated by experimental tests. Moreover, the half-control mode is investigated as a strategy to operate with high efficiency and tolerant mode.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.