Abstract
Increasing the flux-to-voltage transfer coefficient of the SQUID output voltage is necessary to release the constraint on the preamplifier input noise. As one of the approaches to increase the transfer coefficient, we have been using a double relaxation oscillation SQUID (DROS) having a transfer coefficient of about 10 times larger than those of DC-SQUIDs. Traditionally, DC-SQUIDs were operated in the non-hysteretic condition with the Stewart-McCumber parameter (β <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> ) less than 1. In this study, we fabricated hysteretic DC-SQUIDs with the β <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> ranging from 2.5 and compared the transfer coefficient and the system noise of DC-SQUIDs and DROSs. Both DROS and DC-SQUID have the same structure and design parameters for the SQUID loop inductance, resonance-damping circuits in the SQUID loop, and input coil. All the SQUIDs were fabricated in the same wafer using the Nb/AlO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x</sub> /Nb junction process. The transfer coefficients of DROSs were about 1 mV/Φ <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub> , regardless of SQUID parameters. For DC-SQUIDs, the transfer coefficients were sensitive to the β <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> and the operating margin was narrower than that of DROS. The white noise of both SQUIDs in the flux-locked loop mode was around 1.5 μΦ <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0</sub> /√Hz at 100 Hz, measured with a preamplifier of input voltage noise of 1 nV/√Hz. DC-SQUIDs had mostly a narrower operating margin against the bias current, and the modulation voltage was smaller than DROS. In a near-optimized operating condition, both DROS and hysteretic DC-SQUID showed comparable noise performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.