Abstract

Transcranial color-coded duplex Doppler (TCCD) is commonly used to detect and monitor vasospasm in subarachnoid aneurysmal hemorrhage (aSAH). However, contrast enhanced TCCD (CE-TCCD) may be more effective. The objective of this study was to compare the accuracy of TCCD and CE-TCCD in the detection of vasospasm. This study was a prospective comparison of TCCD and CE-TCCD for the detection of vasospasm, using computed tomography angiography (CT Angio)as a reference examination. The setting was the Department of Anesthesiology and Intensive Care at the Bicêtre University Hospital in Le Kremlin Bicêtre, France. TCCD and CE-TCCD were performed in 47 patients admitted to the intensive care unit (ICU) following aSAH over a 7-month period. TCCD and CE-TCCD were performed at ICU admission and between days 7 and 10. We aimed to visualize the seven intracranial arteries of the circle of Willis. Vasospasm diagnosis was assessed byCT Angio and graded as moderate when the percentage change in arterial diameter since admission was between 25 and 50% or as severe when the percentage change was greater than 50%. On ICU admission, TCCD allowed visualization of all intracranial arteries in 16 (34%) of 47 patients, whereas CE-TCCD allowed visualization of all vessels in 37 (79%) of 47 patients (p < 0.001). These results were consistent between days 7 and 10. The proportions of middle cerebral arteries (MCAs), anterior cerebral arteries(ACAs) and posterior cerebral arteries(PCAs) visualized were greater with CE-TCCD. There was no difference in the visualization of basilar arteries(BAs). We performed vasospasm analysis on 67 of 94 MCAs in 47 patients. Area under the curve(AUC) of mean flow velocity to detect MCA vasospasm (moderate and severe) was 0.86 (0.58-1.00) for TCCD and 0.90 (0.77-1.00) for CE-TCCD. AUC of mean velocity to detect severe MCA vasospasm was 0.86 (0.58-1.00) for TCCD and 0.90 (0.77-1.00) for CE-TCCD, without any significant difference between the two techniques. For other arteries, the accuracy of TCCD and CE-TCCD to diagnose vasospasm was poor. CE-TCCD allows better visualization of intracranial arteries in patients with aSAH. The accuracy of CE-TCCD to screen severe MCA vasospasm is similar to that of TCCD. CE-TCCD is an alternative tool for monitoring patients with aSAH without a temporal bone window for an ultrasound.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.