Abstract
<br><b>Aim:</b> This study was conducted aiming to optimize the selection of bar material that can minimize stresses on mandibular bone. <b>Subjects and Methods:</b> One finite-element model was created under ANSYS environment to evaluate the use of different materials as a bar-manufacturing material in mandibular implant-supported overdenture (OD). Model components were created on engineering computer-aided design software and then assembled under the finite-element package. A force of 200 N was unilaterally and vertically applied on the left second premolar area. <b>Results:</b> Within these study conditions, the polyether ether ketone bar produced the lowest Von Mises stress on OD and the maximum value of deformation. Stainless steel bar produced the maximum OD total deformation. <b>Conclusions:</b> Cortical and spongy bones are not sensitive to the bar material. Increasing bar material stiffness increases Von Mises stresses in the bar itself and reduces its total deformation, in what is called overconstrained system.<br>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.