A comparison was made between high-performance liquid chromatography (HPLC) and gas chromatography-mass spectrometry (GC-MS) as methods for determining bupivacaine in human plasma. Both methods utilized pentycaine as an internal standard, were found to be linear in the range 5–320 ng and had acceptable precision and accuracy. The precision for the HPLC method was better than that for the GC-MS method. The limits of detection of the HPLC and GC-MS methods were ca. 1.0 and 0.1 ng, respectively. Good agreement between the HPLC and GC-MS methods was obtained for the analysis of samples taken from a patient receiving bupivacaine topically. For most purposes the HPLC method would be slightly better. However, for samples containing interfering peaks GC-MS provides a higher degree of resolution from such interferants.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.