Abstract
Abstract This paper deals with the stability problem of three stator current error-based estimators of induction motor speed, especially in the regenerating operation mode. The stability of the adaptive full-order observer (AFO) and two model reference adaptive systems (MRASs) based on a stator current error (MRASCCand MRASCV) is briefly analysed, and the stability borders are determined and compared. It is shown that MRASCVspeed estimator is stable in the whole operation range including the regenerating mode without any modifications. The stability enhancement method for AFO and MRASCCestimators is described, and the solution for their stability improvement is proposed. Torque-speed characteristics of the analysed MRAStype estimators in a wide range of drive speed and load torque changes are given, as well as the behaviour of estimators during transients is compared. The theoretical analysis and simulation test results are validated by experimental tests.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.