Abstract
To evaluate the effect of implant position, impression, and tray material on the accuracy of implant impressions of edentulous arches with multiple implants. Four experimental groups were produced; medium-viscosity polyvinyl siloxane (PVS) was used in 3 groups and polyether was used in 1 group. In PVS groups, different tray types were used; metal stock trays, custom acrylic tray, and full-arch perforated plastic trays. In polyether group, custom acrylic trays were used. The discrepancies in 3 dimensions were measured. The casts obtained exhibited small deviations (7.50-9.71 µm) from the master cast. There was no statistically significant difference between the polyether and PVS groups. Similarly, different tray materials did not produce any statistically significant discrepancies within the PVS groups. There was no significant difference among the groups when the accuracy of anterior implants were compared, but within-the-group comparisons showed that except group 1 (GR1), the posterior implants demonstrated more accuracy than anterior ones. Polyether and PVS can safely be used for the impressions of the edentulous arches with multiple implants and different tray types produce similar accuracy results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.