Abstract

A comparative analysis of the influence of the law of motion of the plate of a self-acting valve on the calculation of efficiency indicators of the working process of a piston compressor stage, such as the temperature of the discharge gas, the flow rate and the indicated isothermal efficiency, is presented. Long-stroke, low-speed, and high-speed stages are considered. The conducted studies demonstrate the need to apply the methodology for calculating the dynamics of real valves having elastomeric elements in relation to the stages of low-speed long-stroke compressor units, as well as the relevance of additional studies to clarify the individual components of this method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.