Abstract

With the emergence of RNA sequencing technologies, metatranscriptomic studies are rapidly gaining attention as they simultaneously provide insight into gene expression profiles and therefore disease association pathways of microbial pathogens and their hosts. This approach, therefore, holds promise for applicability in infectious disease diagnostics. A challenge of this approach in the clinical setting is the low amount and quality of RNA, especially microbial RNA in most clinically-infected specimens. Here, we compared two commercially available stranded cDNA library preparation kits, the NuGEN Ovation SoLo RNA-Seq System and the Illumina TruSeq Stranded Total RNA, using RNA extracted from synovial and sonicate fluids from a subject with periprosthetic joint infection. The Ovation SoLo RNA-Seq System provided more useful transcriptomic data for the infecting bacterium, whereas the TruSeq Stranded Total RNA kit provided more useful human transcriptomic data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.